This guide fits the X, Y1 and Y2 inductive limit switches. The Z-axis switch is fitted during 2.3 X-Carriage Assembly.
The Y mounts are mirrored, Y1 is on the side with Drag-Chain-Y; Y2 is on the opposite side. Use the matching drawing for each mount to ensure correct fitment
Tighten the switch and mount fixings gently. Do not overtighten or distort the sensor body or printed mount.
| Image |
Instructions |
 |
- Slide the GX-H8B inductive switch into the locating slot in the X inductive-switch mount. Orient the switch and its cable exit as shown.
- Align the switch mounting hole with the hole in the mount and secure using 1 x 3x12mm Polyfix Screw.
- Insert 2 x M5-Button-Head-Bolt-14mm through the mount and loosely thread on 2 x M5-Drop-In-Tee-Nut.
|
 |
- Fit the mount to the back of Extrusion-E at the Y-Carriage end shown in the drawing.
- Make sure both M5-Drop-In-Tee-Nuts engage with the extrusion slot and the mount sits flat against the extrusion.
- Locate the mount against the Y-Carriage as shown, then tighten the two M5 bolts evenly.
- Check that the sensor is seated in its mount and its cable exits from the rear without being trapped.
|
| Image |
Instructions |
 |
- Select the Y1 inductive-switch mount. Slide a GX-H8B inductive switch into its locating slot, with the cable exit orientated as shown.
- Align the switch mounting hole with the hole in the mount and secure using 1 x 3x12mm Polyfix Screw.
- Insert 2 x M5-Button-Head-Bolt-12mm through the mount and loosely thread on 2 x M5-Drop-In-Tee-Nut.
|
 |
- Fit the Y1 mount to the top slots of Extrusion-F at the rear, motor end of the machine.
- Locate the mount against the rear end plate as shown. Make sure both M5-Drop-In-Tee-Nuts engage with the extrusion slots.
- Check that the mount sits flat, then tighten both M5 bolts evenly.
- Check the sensor orientation against the installed drawing.
|
| Image |
Instructions |
 |
- Select the Y2 inductive-switch mount. Slide a GX-H8B inductive switch into its locating slot, with the cable exit orientated as shown.
- Align the switch mounting hole with the hole in the mount and secure using 1 x 3x12mm Polyfix Screw.
- Insert 2 x M5-Button-Head-Bolt-12mm through the mount and loosely thread on 2 x M5-Drop-In-Tee-Nut.
|
 |
- Fit the Y2 mount to the top slots of Extrusion-F at the rear, motor end of the machine.
- Locate the mount against the rear end plate as shown. Make sure both M5-Drop-In-Tee-Nuts engage with the extrusion slots.
- Check that the mount sits flat, then tighten both M5 bolts evenly.
- Check the sensor orientation against the installed drawing.
|
| Image |
Instructions |
 |
- Lead the X switch cable around the plate as shown. Keep it clear of the moving carriage and do not pull on the sensor cable exit.
- The remaining X cable route and slot cover are fitted during 3.4 Wire Routing.
|

 |
- Guide each Y switch cable around the inside corner of its mount and down the inside face beside the motor, following the drawings.
- Keep the sleeved cable clear of the motor lead, bolts and moving parts. Do not leave a loop hanging across the outside of the motor.
- Leave enough free cable to avoid pulling on the switch. The full routes, extensions and cable retention are covered in 3.4 Wire Routing.
|
| Image |
Instructions |
 |
- Check that all three switches are seated in their mounts and all mounting fixings are secure.
- Check that the cables are not trapped beneath the mounts or resting against moving parts.
- Guide Complete - Proceed to 3.3 Power Supply & Emergency Stop.
|