The Calibration wizard compares a commanded distance with a physical measurement, then calculates a new steps per millimetre value. This controls how many motor steps the controller sends for each millimetre of travel.
Use Measured Travel for X, Y or Z. Use Vernier Scale for X or Y when you want to cut a reference scale and compare it with a steel ruler.
Calibration moves the machine, and the Vernier method cuts material. Keep the travel area clear and the emergency stop accessible.
| Instructions | Preview |
|---|---|
|
![]() |
Select the Measured Travel or Vernier Scale tab below to see its instructions. For the Z axis, use Measured Travel.
The following steps apply to using the Measured Travel method.
| Instructions | Preview |
|---|---|
|
![]() |
|
![]() |
| Instructions | Preview |
|---|---|
|
![]() |
|
![]() |
| Instructions | Preview |
|---|---|
|
![]() |
|
![]() |
| Instructions | Preview |
|---|---|
|
![]() |
| Instructions | Preview |
|---|---|
|
![]() |
This method cuts marks numbered 0 to 100 at 0.9 mm spacing, giving a nominal 90 mm distance from the first mark to the last. Comparing those marks with the millimetre divisions on a steel ruler provides the measurement used for the correction.
| Instructions | Preview |
|---|---|
|
![]() |
| Instructions | Preview |
|---|---|
|
![]() |
The scale includes numbers and dimension graphic. Check the full marking footprint and every travel path against the stock, clamps and toolholder before starting.
| Instructions | Preview |
|---|---|
|
![]() |
|
![]() |
|
![]() |
Wait for the cut to finish, stop the spindle and make sure the machine is stationary.

Starting at the right-hand end, look towards the left for a cut mark that lines up precisely with a millimetre graduation on the ruler.
Compare the centres of the lines, looking directly above them to avoid viewing-angle errors. Ignore the shared zero and use the rightmost clearly aligned pair.

In this example, cut mark 96 lines up with 85 mm on the ruler.

Check the readings, then click Continue. If the zero alignment or matching mark is uncertain, repeat the measurement instead of guessing.
Check Current Steps/mm, New Steps/mm and Error Factor before applying the result. The nominal distance is the chosen mark number multiplied by 0.9 mm.
For the example readings, 400 × (96 × 0.9) ÷ 85 = 406.588 steps/mm. Use your own readings, not these example values.
Click Back to revise a reading, or Apply to write the proposed value to the controller.

After applying, reopen the selected axis's steps-per-millimetre setting under Settings and reread the saved value. Repeat the physical measurement with the same reliable setup and compare the new travel with the commanded distance. For Vernier, cut a fresh scale rather than remeasuring the old one. Keep a fresh settings backup once the result is verified.
| Instructions | Preview |
|---|---|
|
![]() |
Closing the wizard is not an emergency stop and does not guarantee queued movement stops. For an immediate hazard, use the machine's physical emergency stop.